Life safety learning hub

Life Safety Systems

Emergency lighting to BS 5266, evacuation alert systems under BS 8629, sprinkler and suppression systems to BS EN 12845, and dry/wet risers to BS 9990 — the life safety infrastructure that keeps buildings evacuable.

In short

Life safety systems keep people alive during a fire long enough to evacuate or be rescued. Emergency lighting needs monthly function tests and annual 3-hour duration tests. Dry risers need annual wet pressure testing. Evacuation alert systems are mandatory in new high-rise residential over 18 metres.

What the law says

BS 5266-1:2016
Emergency lighting design, installation and testing — monthly function test, annual full-duration test.
BS 9990:2015
Non-automatic fire-fighting systems in buildings — dry and wet risers, annual pressure test.
BS 8629:2019
Evacuation alert systems for use by Fire and Rescue Services in blocks of flats.
BS EN 12845
Fixed fire-fighting systems — sprinkler systems, design and maintenance.

Common problems & fixes

  • Emergency lighting log book gaps
    Fix, Contract a BAFE-registered maintainer for monthly and annual testing, with a digital log accessible to the RP.
  • Dry riser inlet valve seized
    Fix, Annual wet pressure test with a certified specialist — a failure blocks fire service intervention.
  • Sprinkler heads painted over during refurbishment
    Fix, LPS 1048-approved contractor to replace heads and recommission the zone.
  • New high-rise handed over without an EAS
    Fix, Commission a BS 8629 evacuation alert system before occupancy — required for new residential over 18 metres.
Pillar guide6 min read

Emergency Lighting Testing to BS 5266: Duty Holder Guide

Monthly function tests, annual 3-hour duration tests, log book requirements and remediation timelines for emergency lighting under BS 5266-1:2016.

Read the full guide

All life safety guides

1 guide
Cluster guides for this niche are publishing shortly. The pillar guide above covers the full duty-holder journey while we finish the deeper breakdowns.

Frequently asked

How often must emergency lighting be tested?
BS 5266 requires a monthly function test (short) and an annual full-duration test — typically three hours for maintained systems.
Are sprinklers mandatory in high-rise flats?
For new residential buildings in England over 11 metres, Approved Document B requires automatic sprinklers throughout.
What is an evacuation alert system?
A BS 8629 system installed for use by the Fire and Rescue Service to alert residents floor by floor during a fire — mandatory in new-build residential over 18 metres.