Water learning hub
Water Hygiene
Legionella risk assessment, monitoring, sampling and remedial works for duty holders under HSG274 and ACOP L8 — with realistic timelines and cost expectations.
In short
The duty holder must identify and assess the risk of exposure to Legionella and implement written control measures under the Approved Code of Practice L8. Reviews are due at least every two years — sooner if the system, use or risk profile changes.
Legal snapshot
What the law says
- Health and Safety at Work etc Act 1974
- General duty of care to employees and others affected by the undertaking.
- COSHH Regulations 2002
- Legionella bacteria treated as a substance hazardous to health.
- ACOP L8 (4th edition)
- Legionnaires' disease: the control of legionella bacteria in water systems.
- HSG274 Parts 1–3
- Technical guidance on evaporative cooling systems, hot and cold water systems, and other risk systems.
On the ground
Common problems & fixes
- Legionella risk assessment older than 2 yearsFix, Commission a fresh LRA from a Legionella Control Association (LCA) registered assessor.
- Temperature monitoring not recordedFix, Weekly sentinel outlet temperatures logged in a written scheme — hot ≥50°C, cold ≤20°C.
- TMV strainers not descaledFix, Annual TMV service on all high-risk outlets, recorded against the asset register.
- Positive Legionella count from samplingFix, Follow HSG274 Part 2 remediation: superchlorination or thermal disinfection and resample to clear.
Legionella Risk Assessments: HSG274 & ACOP L8 Guide
How to commission, review and act on a Legionella risk assessment under ACOP L8 and HSG274 — control measures, monitoring intervals and remedial routes.
Read the full guideAll water guides
1 guideFAQ
Frequently asked
- Who is the duty holder for Legionella?
- The employer or person in control of the premises where work activities are carried on. Landlords with responsibility for water systems in let premises are also duty holders.
- How often should sentinel outlets be tested?
- Weekly for representative sentinel outlets, monthly for all little-used outlets, and quarterly for calorifier flow and return temperatures — per HSG274 Part 2.
- Do I need to sample for Legionella?
- Sampling is not always required by law but is expected where control measures may not be effective, after an outbreak, or where risk assessment identifies it — typically at least annually in higher-risk systems.
Need water handled now?
Submit a brief and the desk will match you with three verified specialists in 48 hours. Free for building owners and managers, accreditation-verified, no pressure to appoint.
Submit a brief